Norm Set |
Discipline |
Act. Group |
Description |
UOM |
Deliverable |
LE |
SE |
E |
GE |
LD |
SD |
D |
TD |
TC |
Detailed Design |
Electrical |
General |
Mod Initiation |
Per Scope |
False |
9.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
General |
General Support |
Per Scope |
False |
8.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
General |
Project KO / Initiation |
Per Scope |
False |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
General |
Data Retrieval |
Per Scope |
False |
0.0 |
4.0 |
0.0 |
0.0 |
6.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
General |
Progress Reporting and Forecasting |
Per Week |
False |
5.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
General |
Project Meetings |
Per Meeting |
False |
2.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
General |
IDC Review (Internal) |
Per Item |
False |
3.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
General |
Hazid / Envid / TRM / Hazop mtgs. |
Per Meeting |
False |
0.0 |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
General |
Hazid / Envid / TRM / Hazop actions |
Per Action |
False |
0.0 |
5.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
General |
Safety Review |
Per Scope |
False |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
General |
Liaison Mtgs (Client) |
Per Meeting |
False |
3.0 |
3.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
General |
` |
Per Meeting |
False |
2.0 |
2.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
General |
Visit Reports / Minutes of Meeting |
Per Item |
False |
2.0 |
4.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
General |
Project Audit |
Per Meeting |
False |
8.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
General |
Survey Preparation |
Per Survey |
False |
0.0 |
5.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
General |
Offshore Survey - Senior Engineer |
Per Day |
False |
0.0 |
12.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
General |
Survey Report |
Per Survey |
True |
2.0 |
8.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
General |
Cost Estimate, CTRm, AMEST |
Per Scope |
False |
2.0 |
8.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
General |
IDC Approval / Vendor Doc. Review |
Per Item |
False |
0.0 |
3.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
General |
PUWER Review |
Per Meeting |
False |
0.0 |
5.0 |
0.0 |
0.0 |
5.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
General |
Electrical Workscope |
Per Scope |
True |
2.0 |
15.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
General |
Weekly and Monthly Report Generation |
Per Issue |
False |
2.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
General |
People and Work Management |
Per Week |
False |
4.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
General |
Housekeeping and Discipline Audits |
Per Week |
False |
1.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
General |
Input into SOR |
Per Scope |
False |
2.0 |
8.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
General |
Offshore Survey - Designer |
Per Day |
False |
0.0 |
0.0 |
0.0 |
0.0 |
12.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Technical Direction and Control (Design) |
Per Week |
False |
0.0 |
0.0 |
0.0 |
0.0 |
5.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Single Line Diagram (Complex/New) |
Per Item |
True |
1.0 |
4.0 |
0.0 |
0.0 |
20.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Block Diagram (Complex) |
Per Item |
True |
2.0 |
8.0 |
0.0 |
0.0 |
25.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Interconnection Diagram (Complex) |
Per Item |
True |
0.0 |
5.0 |
0.0 |
0.0 |
15.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Termination Diagram (Complex/New) |
Per Item |
True |
1.0 |
5.0 |
0.0 |
0.0 |
15.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Schematic Diagram (Complex/New) |
Per Item |
True |
2.0 |
10.0 |
0.0 |
0.0 |
20.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Protection Diagram (New) |
Per Item |
True |
1.0 |
10.0 |
0.0 |
0.0 |
20.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Electrical Equipment Layout Drawing (PDMS) |
Per Item |
True |
0.0 |
2.0 |
0.0 |
0.0 |
20.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Lighting and Small Power Layout (PDMS) |
Per Item |
True |
0.0 |
2.0 |
0.0 |
0.0 |
20.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Trace Heating Isometric (PDMS) |
Per Item |
True |
0.0 |
5.0 |
0.0 |
0.0 |
12.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Cable Rack / Tray Layout Diagram (2D) |
Per Item |
True |
0.0 |
2.0 |
0.0 |
0.0 |
15.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Cable Routing Diagram (PDMS) |
Per Item |
True |
0.0 |
2.0 |
0.0 |
0.0 |
15.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Cable Rack Isometrics (PDMS) |
Per Item |
True |
0.0 |
2.0 |
0.0 |
0.0 |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Standard Installation Detail (New) |
Per Item |
True |
0.0 |
2.0 |
0.0 |
0.0 |
15.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
PDMS Model Population (Incl. Clash Check) |
Per Line |
False |
0.0 |
0.0 |
0.0 |
0.0 |
45.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Cable Schedule |
Per Item |
True |
0.0 |
2.0 |
0.0 |
0.0 |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Distribution Board Schedule |
Per Item |
True |
0.0 |
2.0 |
0.0 |
0.0 |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Junction Box Schedule |
Per Item |
True |
0.0 |
2.0 |
0.0 |
0.0 |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
MCC Drive Schedule (Complex/New) |
Per Item |
True |
0.0 |
4.0 |
0.0 |
0.0 |
12.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Destruct Drawings - Brownfield |
Per Item |
True |
0.0 |
4.0 |
0.0 |
0.0 |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Construct Drawings - Brownfield |
Per Item |
True |
0.0 |
4.0 |
0.0 |
0.0 |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
PDMS Model Review |
Per Meeting |
False |
5.0 |
0.0 |
0.0 |
0.0 |
5.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Weight Control (Discipline Input) |
Per Issue |
False |
0.0 |
0.0 |
5.0 |
0.0 |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Bulk MTO |
Per Item |
True |
0.0 |
0.0 |
5.0 |
0.0 |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
General Arrangement Drawing (PDMS) |
Per Item |
True |
0.0 |
4.0 |
0.0 |
0.0 |
20.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Asset Register |
Per Item |
True |
0.0 |
2.0 |
0.0 |
0.0 |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Electrical Load Schedule (Simple) |
Per Item |
True |
3.0 |
20.0 |
0.0 |
0.0 |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Single Line Diagram (Simple/Modified) |
Per Item |
True |
1.0 |
3.0 |
0.0 |
0.0 |
15.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Block Diagram (Simple) |
Per Item |
True |
2.0 |
5.0 |
0.0 |
0.0 |
12.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Interconnection Diagram (Simple) |
Per Item |
True |
0.0 |
4.0 |
0.0 |
0.0 |
15.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Termination Diagram (Simple/Modified) |
Per Item |
True |
1.0 |
5.0 |
0.0 |
0.0 |
15.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Schematic Diagram (Simple/Modification) |
Per Item |
True |
1.0 |
5.0 |
0.0 |
0.0 |
15.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Protection Diagram (Modification) |
Per Item |
True |
1.0 |
5.0 |
0.0 |
0.0 |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Electrical Equipment Layout Drawing (2D) |
Per Item |
True |
0.0 |
2.0 |
0.0 |
0.0 |
15.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Lighting & Small Power Layout (2D) |
Per Item |
True |
0.0 |
2.0 |
0.0 |
0.0 |
15.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Trace Heating Isometric (2D) |
Per Item |
True |
0.0 |
5.0 |
0.0 |
0.0 |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Cable Rack/Tray Layout Diagram (PDMS) |
Per Rack/Tray |
True |
0.0 |
2.0 |
0.0 |
0.0 |
20.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Cable Routing Diagram (2D) |
Per Item |
True |
0.0 |
2.0 |
0.0 |
0.0 |
15.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Standard Installation Detail (AMECFW Standard Detail) |
Per Item |
True |
0.0 |
2.0 |
0.0 |
0.0 |
5.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Input to Aveva Electrical |
Per Scope |
False |
0.0 |
5.0 |
100.0 |
0.0 |
50.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
MCC Drive Schedule (Simple/Modification) |
Per Item |
True |
0.0 |
2.0 |
0.0 |
0.0 |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Transit Layout (Modified) |
Per Item |
True |
0.0 |
2.0 |
0.0 |
0.0 |
6.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Point Cloud Interface |
Per Item |
False |
0.0 |
0.0 |
0.0 |
0.0 |
5.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
General Arrangement Drawing (2D) |
Per Item |
True |
0.0 |
4.0 |
0.0 |
0.0 |
15.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Input to Electronic Database (Administration) |
Per Week |
False |
0.0 |
0.0 |
0.0 |
0.0 |
2.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Input to Electronic Database |
Per Week |
False |
0.0 |
0.0 |
0.0 |
0.0 |
8.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Trainee Designer |
Per Day |
False |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
9.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Transit Layout (New) |
Per Item |
True |
0.0 |
2.0 |
0.0 |
0.0 |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Wiring Diagram |
Per Item |
True |
1.0 |
1.0 |
0.0 |
0.0 |
4.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Design |
Sketch |
Per Item |
True |
0.0 |
2.0 |
0.0 |
0.0 |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Engineering |
Technical Direction and Control (Engineering) |
Per Week |
False |
5.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Engineering |
Basis of Design |
Per Item |
True |
40.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Engineering |
Workscope/Statement of Work |
Per Item |
True |
2.0 |
8.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Engineering |
Study Report Input |
Per Item |
False |
2.0 |
8.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Engineering |
Study Report Compilation (Lead Discipline) |
Per Item |
True |
5.0 |
40.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Engineering |
Calculations (Cable Sizing - HV / LV) |
Per Item |
True |
1.0 |
8.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Engineering |
Calculations (Lighting - Per Area) |
Per Item |
True |
0.0 |
2.0 |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Engineering |
Calculations (Trace Heating) |
Per Item |
True |
0.0 |
2.0 |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Engineering |
Calculations (Battery Sizing) |
Per Item |
True |
1.0 |
8.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Engineering |
Calculations (Protection Coordination) |
Per Item |
True |
1.0 |
12.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Engineering |
Power System SLD Model Set up (SKM/ETAP |
Per System |
False |
5.0 |
45.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Engineering |
System Analysis Calculations |
Per Item |
True |
2.0 |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Engineering |
Preparation of Specifications |
Per Item |
True |
2.0 |
30.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Engineering |
Preparation of Elect. Equip. Datasheets |
Per Item |
True |
2.0 |
8.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Engineering |
Electrical Protection Review |
Per Item |
True |
2.0 |
40.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Engineering |
Design Philosophies |
Per Item |
True |
40.0 |
5.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Engineering |
Electrical Load Schedule (Complex) |
Per Item |
True |
5.0 |
60.0 |
0.0 |
0.0 |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Engineering |
Ops & Maintenance Manuals Input |
Per Item |
False |
0.0 |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Engineering |
CCHP Compilation |
Per Workpack |
True |
2.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Engineering |
Technical Note |
Per Item |
True |
0.0 |
9.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Engineering |
Input to Workscope/Statement of Work |
Per Item |
False |
4.0 |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Engineering |
Power System Modelling per Equipment (SKM/ETAP |
Per Item |
False |
1.0 |
4.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Engineering |
Power System Modelling Set up per Scenario (SKM/ETAP) |
Per Scenario |
False |
1.0 |
5.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Engineering |
Power System Equipment Design Report |
Per Item |
True |
5.0 |
45.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Engineering |
Power System Analysis Report |
Per Item |
True |
10.0 |
75.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Engineering |
Electrical Engineering Scope Development |
Per Item |
False |
5.0 |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Engineering |
Input to Multi Discipline Specification |
Per Item |
False |
5.0 |
20.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Engineering |
Checklists |
Per Item |
False |
0.0 |
0.5 |
0.0 |
0.0 |
0.5 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Engineering |
Graduate Engineer |
Per Day |
False |
0.0 |
0.0 |
0.0 |
9.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Procurement |
Equipment Review / Assessment / Report |
Per Item |
True |
5.0 |
15.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Procurement |
Supplier Contact / Budget costs |
Per Item |
False |
0.0 |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Procurement |
Vendor Liaison |
Per Week |
False |
0.0 |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Procurement |
F.A.T. |
Per Day |
False |
0.0 |
12.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Procurement |
Bulk Material Requisition |
Per Item |
True |
2.0 |
4.0 |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Procurement |
Equipment Requisition |
Per Item |
True |
2.0 |
4.0 |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Procurement |
Single Source Justification |
Per Item |
False |
1.0 |
5.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Procurement |
Technical Bid Eval. - Electrical Equipment |
Per Item |
True |
5.0 |
45.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Procurement |
Technical Bid Eval. - Bulk Material |
Per Item |
True |
2.0 |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Procurement |
SDDR |
Per Item |
True |
1.0 |
3.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Procurement |
Criticality Rating Sheet |
Per Item |
True |
1.0 |
3.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Procurement |
Bill Of Materials |
Per Item |
True |
0.0 |
0.0 |
5.0 |
0.0 |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Vendor |
Bid Clarification Meeting |
Per Meeting |
False |
2.0 |
8.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Vendor |
Vendor Mobilisation / Call-off Contract |
Per Mobilisation |
False |
0.0 |
8.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Vendor |
SDDM |
Per Item |
True |
1.0 |
2.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Construction |
Workpack Compilation |
Per Workpack |
True |
0.0 |
8.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Construction |
Construction Review Meeting |
Per Workpack |
False |
0.0 |
5.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Construction |
Construction Liaison / Support |
Per Week |
False |
0.0 |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Construction |
Workpack Narative and Checking |
Per Workpack |
False |
2.0 |
6.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Commissioning |
Commissioning Support |
Per Item |
False |
0.0 |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Commissioning |
Commissioning Procedures Input |
Per Item |
False |
0.0 |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Commissioning |
Commissioning Report |
Per Item |
True |
2.0 |
10.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Follow-on |
Site Queries / EQs |
Per Query |
False |
0.0 |
5.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Follow-on |
Follow On - Lead Engineer |
Per Day |
False |
9.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Follow-on |
Follow On - Designer |
Per Day |
False |
0.0 |
0.0 |
0.0 |
0.0 |
9.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Close-out |
Supplier Document Close-out |
Per Supplier |
False |
0.0 |
30.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Close-out |
Discipline File Close-out |
Per Scope |
False |
0.0 |
20.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|
Detailed Design |
Electrical |
Close-out |
As-Built Drawing |
Per Item |
False |
1.0 |
0.0 |
0.0 |
0.0 |
5.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Update
| Delete
|